If there's an alarm, you'll know it even in noisy conditions thanks to the wide-angle flash, along with the audible and vibrating alerts. It flashes red when a bump test is due or a gas event occurs. This way, workers can help each other improve safety by easily spotting non-compliant detectors. The BW Clip is up to three years maintenance-free. Just turn on the detector and it runs continuously. Thus no need for calibration, sensor replacement, battery replacement, or battery charging, which means great reliability and no downtime. When you use the two-year BW Clip for H2S or CO, you can hibernate the detector when you're not using it. By hibernating the detector, you can extend its usual life of 2 years up to 3 years. Instead, daily self-test happens automatically. If it finds an issue in critical functionality, it will shut down the detector to protect you from unsafe use. Up to three years for two-year H2S and CO detectors when used with the hibernation feature, limited to 24 months of detector operation. BW Gas Alert Clip Extreme 36 Month Gas Detectors. Long term solution for single gas detection. The bright, large LCD shows real-time gas concentrations and the instrument's status at all times. We carry the entire BW line of gas monitors including the Gas Alert Extreme, Gas Alert Clip Extreme, Gas Alert Quattro, Gas Alert Max XT II, Gas Alert Microclip XT, Gas Alert Micro 5, Gas Alert Micro 5 PID and IR, Microdock II, and all of the replacement sensors. It is your responsibility to respond appropriately to the alarms. Operator s Manual 1, 2, 3, and 4-Gas Detector. The GasAlert Extreme offers real-time readings and extended longevity with a two year field-replaceable battery and sensor. Transmit Gas Event Data The detector stores the last 10 events such as maximum gas exposure, bump. Table of Contents extreme circumstances can impair the sensitivity of the LEL sensor. BW Technologies by Honeywell Gas Alert Series Gas Monitors from JJS. http://gites-belluire.com/UserFiles/credit-policy-and-procedure-manual.xml
bw gas alert clip 2 manual, bw gas alert clip 2 h2s extreme user manual, bw gas alert clip 2 manual, bw gas alert clip 2 manual pdf, bw gas alert clip 2 manual free, bw gas alert clip 2 manual online, bw gas alert clip 2 manual 2017, bw gas alert clip 2 manual instructions, bw gas alert clip 2 manual downloads, bw gas alert clip 2 manual youtube, bw gas alert clip 2 manual 2016.
View and Download BW Technologies BW Clip operator's manual online. Your source for all of your BW Technologies Gas Monitor needs. It operates bw gas alert clip extreme 2 manual for up to three years with zero maintenance. GasAlert Extreme Quick Reference Guide Deactivating the detector resets the time-weighted average (TWA), short-term exposure limit (STEL), and maximum gas exposure values to 0. It is bw gas alert clip extreme 2 manual designed to be worn by technicians and others who work in and around combustion devices. Move to a normal atmosphere ( O 2) that is free of hazardous gas. Calibration is a simple automatic procedure and is compatible with BW Technologies' MicroDock II automatic test and calibration system.Model Gas Monitored GasAlert Extreme O 2 Oxygen ( by volume) GasAlert Extreme CO Carbon monoxide (ppm) Low H bw gas alert clip extreme 2 manual GasAlert Extreme User Manual Contacting BW Technologies To contact BW Technologies, call: USA: G Clip 6. BW Clip Real Time continuously displays the concentration of a specific. Model Gas Monitored GasAlert Extreme O2 Oxygen GasAlert Extreme User Manual 2 Contacting BW Technologies by Honeywell To contact BW Technologies by Honeywell, call. Before using. Help us improve this article with your feedback. GasAlert Extreme Getting Started. This 2-Year BW Clip from BW Technologies is a maintenance-free, single gas detector for carbon monoxide. After any gas exposure that causes an alarm in the toxic 10 bw gas alert clip extreme 2 manual Alligator clip 2 Visual alarm indicator (red LED) 5 Combustible (LEL) sensor. BW TECHNOLOGIES BY HONEYWELL bw gas alert clip extreme 2 manual GasAlertClip Extreme 2 or 3 Year Gas Detector Instruction Sheet Introduction The GasAlertClip Extreme gas detector (“the detector”) is a personal safety device that warns when hazardous gas exceeds factory set alarm setpoints. http://personnelcle.com/userfiles/credit-policy-manual-for-a-commercial-bank.xml
GasAlertClip Extreme - 2 year As the world’s most popular and widely used zero-maintenance gas detector, the GasAlertClip Extreme offers continuous, reliable protection. BW Technologies by Honeywell recommends the detector be charged after every workday. Calibration is a simple automatic procedure and is compatible with BW Technologies' MicroDock II automatic test and calibration system. The BW GasAlert Extreme Gas Detector is available in a variety of single gas models with datalogging included. Single Gas Detector User Manual. This product is now obsolete and has been replaced by the Clip. BW Technologies GasAlert Extreme single gas detector offers reliability and ease of use with large, real-time readings and a range of user-settable options. How often does my BW Technologies monitor need to be calibrated.Display Elements. 2 If the detector is damaged or parts are missing, contact BW Technologies by Honeywell immediately. GasAlertClip Extreme 2-Year Single Gas Detector - Up to three years of continuous maintenance-free protection As the world's most popular and widely used zero-maintenance gas detector, the. This gas monitor bw gas alert clip extreme 2 manual is the updated model of BW's discontinued GasAlert Clip Extreme for H2S (GA24XT-H). BW Technologies GasAlert Max XT II Gas Calibration Guide by Ideal Calibrations - Duration: GasAlert Extreme Quick Reference Guide 2 Deactivating the detector resets the time-weighted average (TWA), short-term exposure limit (STEL), and maximum gas exposure values to 0. It is a 2-year detector that can be used as a personal H2S monitor for oil, gas, and industrial applications, among others. BW Technologies GasAlert Extreme Single gas monitor - Gas Alert Extreme Single Gas Monitor by BW Technologies What it does Single Gas monitor which detects one of the following gases: CO, H2S, O2.. ? Use only BW approved batteries for your GasAlertMicroClip model 7 Alligator clip 7. https://brandnewhomes.co/new-construction-homes/al/elementary-differential-equations-solutions-manual-pdf-edwards
BW TECHNOLOGIES BY HONEYWELL GasAlertClip Extreme 2 or bw gas alert clip extreme 2 manual 3 Year Gas Detector Instruction Sheet Introduction The bw gas alert clip extreme 2 manual GasAlertClip Extreme gas detector (“the detector”) is a personal safety device that warns when hazardous gas exceeds factory set alarm setpoints. It is a 2-year detector that can be used as a personal H2S monitor for oil, gas, and industrial applications, among others. The BW Technologies GA24XT-H GasAlertClip 2-year H 2 S detector is a handheld, single-gas detector that uses an electrochemical cell sensor to monitor hydrogen sulfide (H 2 S) levels consistently for up to two years without requiring calibration, recharging, or battery replacement, and that has audio, visual, and vibration alarms, which alert simultaneously when H 2 S reaches the preset low. On Sale BW GA24XT-H Personal Gas Detection. Fixed Gas Detection. BW GasAlert Extreme A2 configured for Ammonia detection (ppm NH3) used for personnel protection in. Ongoing product research enables BW Technologies to develop the most advanced workplace safety instruments in the industry. It is your. GasAlert Clip Extreme The GasAlertClip Extreme 2 or 3 year gas detector (“the detector”) is a If the second attempt fails, contact BW Technologies by. Available in two year or three year versions, this single gas detector requires no calibration, sensor replacement, battery replacement, or battery charging. 2. GasAlertMicroClip User Manual Table 4. Single Gas Detector O2, CO, H2S, PH3, SO2, CI2, NH3, NO2, HCN, ETO, CIO2, O3, or NO. Sorry we couldn't be helpful. Help us improve this article with your feedback. As the world’s most popular and widely used zero-maintenance gas detector, the GasAlertClip Extreme offers continuous, reliable protection. GA24XT-H GasAlertClip Extreme 2 Year Single Gas Detector Hydrogen Sulfide (H2S) by BW Technologies. https://fiaxell.com/images/canon-tc-5000-manual.pdf
We have been Canada's premiere industrial supplier for over years with superior service and quality. BW Clip Real Time is a portable, single-gas detector manufactured by BW Technologies by Honeywell (BW). The BWC2-H BW Clip Single Gas bw gas alert clip extreme 2 manual H2S Monitor is a two-year maintenance gas detector that helps keep industrial workers safe in hazardous environments. GasAlertClip Extreme CO 25 ppm GasAlertClip Extreme H 2 S 5 ppm GasAlertClip Extreme SO 2 3 ppm Perform Auto Zero 1. Up to three years of continuous maintenance-free protection As the world's most popular and widely used zero maintenance gas detector, the GasAlertClip Extreme offers continuous, reliable protection. The BW Technologies GAXT-X-DL-2 GasAlert oxygen (O 2) single-gas detector is a handheld, single-gas detector that uses an electrochemical cell sensor to measure oxygen continuously, and that has audio, visual, and vibration alarms, which alert simultaneously when oxygen reaches either of two preset levels. What is the Part number bw gas alert clip extreme 2 manual of a replacement Oxygen (O2) Sensor for BW Gas Monitors. What is a bump check. BW Technologies GA24XT-H GasAlertClip Extreme2 24 Month Gas Detector. Calibrate only in a safe area that is free of hazardous gas. Alarm set points in this device are preset to 10 ppm and 15 ppm. The GasAlert Extreme offers longevity of use with replaceable battery and sensor and tamper-proof user options. How often does my BW Technologies bw gas alert clip extreme 2 manual monitor need to be calibrated. The GasAlert Extreme gas detector (“the detector”) is designed to warn of hazardous gas levels. BW Technologies GasAlert Extreme Single gas monitor - Gas Alert Extreme Single Gas Monitor by BW Technologies What it does Single Gas monitor which detects one of the following gases: CO, H2S, O2. The slim and compact GasAlert MicroClip provides affordable protection from atmospheric hazards.
We carry the entire BW line of gas bw gas alert clip extreme 2 manual monitors including the Gas Alert Extreme, Gas Alert Clip Extreme, Gas Alert Quattro, Gas Alert Max XT II, Gas Alert Microclip XT, Gas Alert Micro 5, Gas Alert Micro 5 PID and IR, Microdock II, and all of the replacement bw gas alert clip extreme 2 manual sensors. Single Gas Detector O2, CO, H2S, PH3, SO2, CI2, NH3, NO2, HCN, ETO, CIO2, O3, or NO. BW Clip Measuring Instruments pdf manual download. We Price bw gas alert clip extreme 2 manual Match. It is designed to be worn by technicians and others who work in and around combustion devices. Be the first to review this product. 2 sensitivity GasAlert Extreme CO Carbon monoxide (ppm) GasAlert Extreme H 2S Hydrogen sulfide (ppm) High range Model Gas Monitored GasAlert Extreme H 2S Hydrogen sulfide (ppm) GasAlert Extreme PH 3 Phosphine (ppm) GasAlert Extreme SO 2 Sulfur dioxide (ppm) GasAlert Extreme Cl 2 Chlorine (ppm) GasAlert Extreme NH 3 Ammonia (ppm) GasAlert. Ammonia Gas Detectors; Carbon Dioxide Gas Detectors; BW GasAlert Extreme Ammonia Detector. 2 bw gas alert clip extreme 2 manual OR 3 YEAR H2S CO O2 bw gas alert clip extreme 2 manual SO2 SINGLE-GAS DETECTOR. Find your bw gas alert clip extreme 2 manual BW TECHNOLOGIES GA24XT-S BW GAS ALERT CLIP EXTREME2 at Acklands-Grainger. GasAlert Extreme. GasAlert Extreme High Range Hydrogen Sulfide (H2S) Single Gas Detector, ppm Measuring Range, Yellow Compact and affordable, the GAXT-HDL GasAlert Extreme reliably monitors for H2S gas hazard within its expanded range of ppm. GasAlert Extreme 1 Introduction This quick reference guide provides basic information to bw gas alert clip extreme 2 manual oper- ate the GasAlert Extreme gas detector.The LCD displays ZEr ppm. Designed with durability and comfort in mind, the GasAlert Extreme reliably monitors for any single gas hazard within its wide range of available toxic gas models.
As its name implies, the GasAlertClip Extreme works by triggering an alert to notify workers when a gas set point is exceeded, and when there’s an increased risk of poisoning. Before using. Order Number: BW-GAXT-A2-DL. Find your BW TECHNOLOGIES GASALERT EXTREME HCN at Acklands-Grainger. BW Clip Real Time continuously displays the concentration of a specific. If self-test has not been completed in the previous 22 hours, the detector performs self-test. The BW Honeywell GasAlertClip Extreme 2 Year CO Monitor is a lightweight and portable ambient carbon monoxide monitor.What is the Part number of a replacement Oxygen (O2) Sensor for BW Gas Monitors. The 2-Year BW Clip H2S Monitor is a maintenance-free, single gas detector for hydrogen sulfide detection. Limited Warranty and Limitation Liability BW Technologies LP (BW) warrants the product to be free from de fects in material and workmanship under normal use and service for a period of two years, beginning on the date of GasAlert Extreme User Manual GasAlert Extreme User Manual 2 Contacting BW. This detector can be your everyday companion for hazardous environments. Calibration is a simple automatic procedure and is compatible with BW’s MicroDock II automatic.View and Download BW Technologies GasAlert Extreme quick reference manual online. BW Technologies GasAlert Max XT II Gas Calibration Guide by Ideal Calibrations - Duration: This product is now obsolete and has been replaced by the Clip. ? Charge the detector before first-time use. BW GasAlert Extreme Single Gas Detectors Series Offers. Up to three years of continuous maintenance-free protection As the world's most popular and widely used zero maintenance gas detector, the GasAlertClip Extreme offers continuous, reliable protection. Press and hold C for 3 bw gas alert clip extreme 2 manual seconds. {-Variable.fc_1_url-
GasAlert bw gas alert clip extreme 2 manual Extreme User Manual Order Number Description GAXT-X bw gas alert clip extreme 2 manual GasA lert Extreme O 2 GAXT-M2 GasAlert Extreme CO (low H 2 sensitivity) GAXT-M GasAlert Extreme CO GAXT-H2 GasAlert Extreme H 2S (high range) GAXT-H GasAlert Extreme H 2S GAXT-P GasAlert Extreme bw gas alert clip extreme 2 manual PH 3 GAXT-S GasAlert Extreme SO 2 GAXT-C GasAlert Extreme Cl 2 GAXT-A GasAlert Extreme NH 3. GasAlert Clip Extreme The GasAlertClip Extreme 2 or 3 year gas detector (“the detector”) is a For more information, contact BW Technologies by Honeywell. The detector stores and transmits gas alarm event data. BW Honeywell GasAlertClip Extreme 2 Year CO Monitor. Available in two year or three year versions, this single gas detector requires no calibration, sensor replacement, battery replacement, or. Ongoing product research enables BW Technologies to develop the most advanced workplace safety instruments in the industry. GasAlert Extreme HCN. This gas monitor is the updated model of BW's discontinued GasAlert Clip Extreme for H2S (GA24XT-H). Transmit Gas Event Data The detector stores the last 10 events such as maximum gas exposure, bump test, and auto zero. The recorded data includes. The device is also optimised to deliver guaranteed compliance to the latest standards and regulations required for bump testing, helping to make your site safer. Ready to use, The GasAlertClip Extreme provides up to three years of continuous maintenance-free operation from the day of activation, with no battery or sensor replacement. This BW gas detector is the user-friendly option with single gas protection in an affordable and compact unit. Long term solution for single bw gas alert clip extreme 2 manual gas detection. ? Charge the GasAlertMicroClip using the recommended charging adapter only. View and Download BW Technologies GasAlert Extreme quick reference manual online.
The BW Honeywell GasAlertClip Extreme 2 Year CO Monitor is a lightweight and portable ambient carbon monoxide monitor. 2 or yeAr gAs deTecTor GasAlert Clip Extreme The GasAlertClip Extreme 2 or 3 year gas detector (“the detector”) is a personal safety device that warns when hazardous gas exceeds factory set alarm setpoints. Sorry we couldn't bw gas alert clip extreme 2 manual be helpful. Do not use the detector if it is damaged. Available in two year or three year versions, this single gas detector requires no calibration, sensor replacement, battery replacement, or battery charging. We take purchase orders and can provide special school, government and corporate pricing. BW Gas Alert Clip Extreme 36 Month Gas Detectors. ? Use only BW approved batteries for your GasAlertMicroClip model (see Specifications). BW Technologies GasAlert Extreme single gas detector offers reliability and ease of use with large, real-time readings and a range of bw gas alert clip extreme 2 manual user-settable options. 2 OR 3 YEAR H2S CO O2 SO2 SINGLE-GAS DETECTOR. The detector stores and transmits gas For more. GasAlert Clip Extreme The GasAlertClip Extreme 2 or 3 year gas detector (“the detector”) is a If the second attempt fails, contact bw gas alert clip extreme 2 manual BW Technologies by Honeywell. Do not. We are here for you. We understand safety and customer service. Comes with a 1 ft. sample probe, 10 ft.Comes with a 1 ft. sample probe, 10 ft.Please try again. This warranty extends only to the sale of new and unused products to the original buyer. BW’s warranty obligation is limited, at BW’s option, to refund of the purchase price, repair or replacement of a defective product that is returned to a BW authorized service center within the warranty period. GasAlert Extreme HCN Hydrogen cyanide (ppm) This manual includes examples from each model. GasAlert Extreme ETO Ethylene oxide (ppm) Table 1. Before using the detector, inspect the case.
Refer to Replacement Parts and Accesso- ries. Use only BW Technologies by Honeywell replace- ment parts. Refer to Replacement Parts and Accessories. While holding, press to enable or disable the confidence beep during start-up. To activate the detector, press in a safe area, free of hazardous gas. Year: The LCD displays Self-Test the current year (20XX). If the sensor test 7. TWA Alarm Setpoint: The LCD displays the TWA alarm set- fails, the detector beeps slowly, the LEDs flash slowly, and point. ALARM flashes. Press to acknowledge the warning message.The LCD beeps, vibrates, and BUMP FAIL displays:. When the confidence beep is enabled, the detector If Deactivation Passcode Protection is enabled, the detector beeps every 5 seconds. Press confirm the selection and access the EXIT screen. Note Note When selecting a user option, Set flashes and the LCD dis- plays the opposite of what is currently enabled. When entering user options, the EXIT screen displays immediately fol- lowing the options (OPTN) screen. The LCD automatically returns to the Note EXIT screen after a user option has been accessed. To disable the passcode protection option, complete the following: options. If the detector is passcode protected to prevent deactivation, OFF displays briefly and then PASS immediately displays. If the option is not confirmed by pressing within 10 seconds, the detector returns to normal operation. The calibration begins automatically during start-up after the calibration 1. From the EXIT screen, press to scroll to the LTCH due screen displays. The Spanish (ESPA) option enables the LCD to display text in Spanish. Note If the multi-language option is included, the detector is shipped with English selected as the default language. The LCD then displays the French 3. Press to scroll to another user option or press exit screen.Datalogger Sampling Rate Option The datalogger sampling rate (RATE) option defines how often the detector records a datalog. During an alarm condition, the detector activates the backlight and the LCD displays the current ambient gas reading. To change the factory-set alarm setpoints, refer to Calibration and Setting Alarm Setpoints. The LCD displays the TWA during a work shift. The detector automatically resets the TWA, gas exposure first. If a low battery alarm occurs, follow your company’s safety procedures. 2. If the calibration past due user option is enabled and the detector. Allow the sensor to stabilize before starting calibration (used: 60 seconds;. Refer to Table 10 and Figure 3 for installation information. Note Only use the calibration cap during calibration. Table 10. Test Cap. When the auto zero is complete the detector beeps Calibration requires several steps, some of which can be bypassed. A twice. note is added to each option that can be bypassed. The passcode is required to access the auto To bypass the set span function, press to automatically pro- span and alarm setpoint functions. To bypass the span function, press to automatically pro- Unsuccessful Span ceed to the alarm setpoint screens. If the span is bypassed, the calibration due date cannot be changed. BW Technologies by Honeywell recommends that the detector be calibrated every 180 days (6 months). The detector is 13. Press to save the new value and proceed to the STEL alarm shipped with the factory default setting of 180 days. The detector automatically proceeds to the low press. Rear Shell Seal Table 13. Front Shell Seal Item Description Item Description Seal Seal. To avoid possible personal injury, adhere to the following: 3. Remove the battery. Gently rock the sensor back and forth to remove a tightly held 5. To clear a sensor, move the detector to a clean environment and wait 10 to 30 minutes. Note Do not expose a sensor to the vapors of inorganic solvents,. If the problem persists, contact BW Technologies by Honeywell. Table 14. Troubleshooting Tips Problem Possible Cause Solution The detector does not activate. No battery Install a battery. Troubleshooting Tips Problem Possible Cause Solution The detector does not display a normal Target gas is present Detector is operating properly. Use caution ambient gas reading after the activation in suspect areas. self-test. Detector requires calibration Calibrate the detector. Troubleshooting Tips Problem Possible Cause Solution The detector intermittently enters alarm Ambient gas levels are near alarm setpoint Detector is operating normally. Use caution mode without apparent reason.GA-BSPLASH-K Splash guard filters To order any parts or accessories, contact BW Technologies by Honey- GA-HC-1 Hard hat clip well. GA-AG-1 Alligator clip (non-conductive) Table 15. All rights reserved. You must have JavaScript enabled in your browser to utilize the functionality of this website. Consultancy Project Management Technical Support Training Courses Product Bulletins Legislation Projects Guides What We Do About Us Our Vision Our People Employment Opportunities Our Charity Work News Contact Search By Gas Top 25 Gases Ammonia Gas Detection Arsenic Detection Carbon Dioxide Gas Detection Carbon Monoxide Gas Detection Chlorine Gas Detection Chlorine Dioxide Gas Detection Ethylene Oxide Gas Detection Formaldehyde Gas Detection Hydrogen Chloride Gas Detection Hydrogen Peroxide Detection Hydrogen Sulphide Gas Detection Hydrogen Cyanide Gas Detection Isocyanate Detection Methane Detection Nitrogen Oxides Detection Nitrogen Dioxides Detection Oxygen Detection Ozone Detection Peracetic Acid Phosphine (PH3) Detection Sulphur Dioxide Detection Trichloroethylene Detection Mercaptan Gas Detection Our portfolio, combined with years of knowledge and expertise means we are able to offer a diverse range of engineered solutions. Please fill in the form below and we will get back to you as soon as possible. Operator’s Manual. Heidi LeuryTable of Contents. Table of Contents. Limited Warranty and Liability. Contact BW Technologies by Honeywell. Corporate Headquarters.8. United States.8. Europe.8. Asia Pacific.8. Email.8. Web.8. Glossary of Terms. Common Terms.9. Warnings and Cautions.10. Important Safety Information: Read FirstWireless Model.13. Intended use.13. Confined Spaces.13. About this Manual.13. Getting StartedImpactXtreme Wireless Model.14. Accessories.14. Buttons.15. Standard Model.15. Wireless Model.15. Enter Button.15. Up Button.16. Down Button.16. Status Icons.16. LCD Backlight.17. LED Visual Alarm Indicators.18. Sensor Poisons and ContaminantsRelated Topics.20. Activate the Detector.21Deactivate the Detector.21. Start-up Sequence.21. CalibrationRelated Topics.26. Calibrate the Detector.26. Bump TestRelated Topics.30. Bump Test the Detector.30Related Topics.33. Zero CalibrationZero Calibration.35. AlarmsGas Alarms.37. Low Alarm.37. High Alarm.37. STEL Alarm.38. TWA Alarm.38. OL Alarm.39. Multi-Gas Alarm.39. Battery Alarms.39. Low Battery Alarm.39. Critical Low Battery Alarm.40. Panic Alarm.40. Detector Behavior.40. Alkaline Battery PackBefore you begin.41. Remove the Alkaline Battery Pack.41. Insert the Alkaline Battery Pack.42. Replace Spent Alkaline Batteries.42. Before you begin.42. Related Topics.42. Rechargeable Battery PackRemove and Insert the Rechargeable Battery Pack.44. Before you begin.44. Remove the Rechargeable Battery Pack.44. Insert the Rechargeable Battery Pack.45. Charge the Rechargeable Battery in a Deactivated Detector.46. Before you begin.46. Related Topics.47. Charge While the Rechargeable Battery is Inserted in a Deactivated Detector.47. Remove and Charge the Rechargeable Battery Pack.48. Coin Cell BatteryBefore you begin.50. Remove Spent Alkaline Batteries.50. Remove and Dispose of the Rechargeable Battery Pack.50. Before you begin.50. Remove the Rechargeable Battery Pack.50. Remove the Coin Cell Battery.51. Before you begin.51. Remove the Coin Cell Battery.52. SensorsRemove the Front Cover.53. Replace a Gas Sensor.53. Replace a Dummy Sensor with a Gas Sensor.54. Insert a Dummy Sensor.54. Maintenance and CleaningGetting Started.57. General Settings.57. Owner Name.58. Distributor Name.58. Distributor Contact Information.58. Language.59. Confidence Beep Interval (seconds).59. Backlight Timeout (seconds).59. Datalog Interval (seconds).59. Log Threshold (FS).59. Device Time.60. Device Configuration Options.60Enable Calibration Lock.60. Enable Fault Protection Lock.60. Enable Force Calibration.60. Enable Flammable Menu.60. Enable PID Menu.60. Enable Wireless Mode Selection.60. Show Environmental Values on Review Mode.60. Show Time on Review Mode.61. Message Configuration.61. Messages.61. Responses.61. Startup Message.61. Configuration Password.61. Sensor and Profile Configuration.61. Profile Configuration.62. Enable Confidence Beep.62. Enable Confidence Flash.62. Enable Beep Per Key Press.62. Enable Latching Alarms.62. Enable GPS.62. Enable WiFi.62. Default Operation Mode.62. Standard.63. Sensor Configuration.63. Detector Information.63. Stealth Mode.63. TroubleshootingWeight.65. Operating Temperature.65. Accuracy specification of combustible gas performance.65. Storage Temperature.65. Operating Humidity.65. Dust and Moisture Ingress.65. Alarm Setpoints.66. Detection Ranges.66. Sensor Types.66. O2 Measuring Principle.66. Bump test specified limits.66. Alarm Conditions.66. Audible Alarm.66. Visual Alarm.67. Display.67. Backlight.67. Internal Vibrator.67. Self-test.67. Calibration.67User Options.67. Sensor Options.67. Year of Manufacture.68. Alkaline Battery Pack and Batteries.68. Approved Alkaline Battery Pack.68. Approved Alkaline Batteries.68. AA Alkaline Battery Operating Time.68. Rechargeable Battery Pack and Lithium Battery.68. Approved Lithium Battery for ImpactXtreme.68. Rechargeable Battery (part number).68. Lithium Battery Operating Time.68. Battery Charger.68. First-time Charge.68. Normal Charge.68. Warranty.69. EC Declaration of Conformity.69. Approvals.69Firmware.69. FCC Statement.69. FCC Caution.69. IC-DFS Statements.69. Replacement Parts and AccessoriesLimited Warranty and LiabilityThis warranty extends only to the sale of new and unusedBW’s warranty obligation is limited, at BW’s option, to refund ofIn no event shall BW’s liability hereunderThis warranty does not include:The obligations set forth in this warranty are conditional on:No goods shall be returned to BW until receipt by theThe buyer agrees that this warranty is the buyer’s sole and exclusive remedy and is in lieu of allBW shall not be liable for any special, indirect,Since some countries or states do not allow limitation of the term of an implied warranty, orIf any provision of this warranty is held invalid orContact BW Technologies by Honeywell. Corporate Headquarters. BW Technologies by HoneywellCalgary, AB. Canada T2A 7X9. Tel. Toll-free:United States. BW Technologies by HoneywellLincolnshire, ILToll-free:Europe. BW Technologies by HoneywellNuffield Industrial Estate. Poole, Dorset BH17 0RZ. Fax. Asia Pacific.